LWE10225 : Sybase SQLAnywhere: Error when trying to run different database Engines with same name on same subnet

Symptom:

Two identical configured SQLAnywhere servers on same collision domain - only the first to be started gets his SQLAny-service /-deamon running

Cause:

SQLAnywhere servers communicate database information via broadcast by default

Solution:

In order to change the default behaviour, start the SQLAny - service with parameter "-x tcpip(DoBroadcast=NO)".