Windows DatabaseebooksStatistical Information

LWE10218 : PassThrough PNAgent client shows ClientName of Server and not the Originating Workstation

Symptom:

The 6.x versions of PNAgent were not designed to act as a pass-through client

Cause:

Use Version PN Agent 7.0 and higher; Workaround for Win32 ICA Client 6.20 see below.

Solution:

Workaround for 6.x PN Agent ICA Client as pass-through client: 

Registry Key: HKEY_LOCAL_MACHINE\SOFTWARE\Citrix\ICA Client\PASS THROUGH
Value Name: PASS THROUGH
Value Type: REG_DWORD
Values:  0 or 1

1 persuades the pass-through client to use the original Client name


The problem might still occur, when using an ICA Client 6.3x; here only an upgrade to version 7 und higher helps - or use Program Neighborhood classic as pass-through client.


Disclaimer:

The information provided in this document is intended for your information only. Lubby makes no claims to the validity of this information. Use of this information is at own risk!
Copyright © 2004-2011 Lubby (V3.0.10 Aug 2011)
Sponsored by Keskon.
Statistical information by Google Analytics