LKBEN10778: PassThrough PNAgent client shows ClientName of Server and not the Originating Workstation


This article has not been checked!

LKB | Created: 02/04/2020 | Version: 0 | Language: EN | Rating: 0 | Outdated: False | Marked for deletion: False

Author: Wim Peeters - Keskon GmbH & Co. KG


Symptom

The 6.x versions of PNAgent were not designed to act as a pass-through client

Cause

Use Version PN Agent 7.0 and higher; Workaround for Win32 ICA Client 6.20 see below.

Solution

Workaround for 6.x PN Agent ICA Client as pass-through client: 

Registry Key: HKEY_LOCAL_MACHINE\SOFTWARE\Citrix\ICA Client\PASS THROUGH
Value Name: PASS THROUGH
Value Type: REG_DWORD
Values:  0 or 1

1 persuades the pass-through client to use the original Client name


The problem might still occur, when using an ICA Client 6.3x; here only an upgrade to version 7 und higher helps - or use Program Neighborhood classic as pass-through client.

About the Author

Wim Peeters is electronics engineer with an additional master in IT and over 30 years of experience including time spent in support, development, consulting, training and database administration. Wim has worked with SQL Server since version 6.5. He has developed in C/C++, Java and C# on Windows and Linux in different European countries and different European languages. He writes knowledge base articles to solve IT problems and publishes them on the Lubby Knowledge Platform where he is one of the most important contributors and the main developer.